Construction

Floor Joist Design (Key Factors to Consider)
Beams placed at ground floor level are called floor beams. Floor beam sizing is designed to accommodate the vertical loads on the beams, the loads transmitted by the floor slabs...
Floor Joist Design (Key Factors to Consider)
Beams placed at ground floor level are called floor beams. Floor beam sizing is designed to accommodate the vertical loads on the beams, the loads transmitted by the floor slabs...

Redistribution of moments in reinforced concret...
What is momentum redistribution? The answer is not entirely simple. The redistribution of moments in concrete beams occurs for several reasons. Some of them are related to strategic analysis...
Redistribution of moments in reinforced concret...
What is momentum redistribution? The answer is not entirely simple. The redistribution of moments in concrete beams occurs for several reasons. Some of them are related to strategic analysis...

Print block design (theory and worked example)
The pressure block design is designed to absorb forces caused by changes in the direction of liquid flowing through the tubes. A change in momentum creates external forces on the...
Print block design (theory and worked example)
The pressure block design is designed to absorb forces caused by changes in the direction of liquid flowing through the tubes. A change in momentum creates external forces on the...

14 Types of Structural Forms for Tall Buildings
Structural forms, also called structural systems, are mechanisms that guarantee the structural stability of a building. Depending on the type of structure, one or more structural systems...
14 Types of Structural Forms for Tall Buildings
Structural forms, also called structural systems, are mechanisms that guarantee the structural stability of a building. Depending on the type of structure, one or more structural systems...

What is the catchment area of the speakers?
Knowing the methods for calculating the column catchment area is important when calculating the axial loads on the column. For manual calculations, the catchment area is the key factor in...
What is the catchment area of the speakers?
Knowing the methods for calculating the column catchment area is important when calculating the axial loads on the column. For manual calculations, the catchment area is the key factor in...

Performance-based building design
Performance Based Design is a method for designing structures with predictable performance for initially considered loads. This approach is used to design a new building or evaluate an...
Performance-based building design
Performance Based Design is a method for designing structures with predictable performance for initially considered loads. This approach is used to design a new building or evaluate an...